KEYSIGHTKeysight High-Voltage Differential Probe N2790A-N2791A -N2891A Datasheet datasheet.pdf
KEYSIGHTKeysight High-Voltage Differential Probe N2790A-N2791A -N2891A Manual manuals.pdf
KEYSIGHTKeysight High-Voltage Differential Probe N2790A-N2791A -N2891A Datasheet datasheet.pdf
KEYSIGHTKeysight High-Voltage Differential Probe N2790A-N2791A -N2891A Manual manuals.pdf
User-selectable 50:1 or 500:1 attenuation settings
At 1 MHz, with common-mode rejection ratio >50 dB, rated differential voltage measurement up to 1400 VDC + AC peak.
Overrange indicator alerts the user when the probe input exceeds the probe's dynamic range
AutoProbe interface
Two point-and-probe tips
Two retractable hook probes
Two alligator clips
Keysight InfiniiVision 3000 X Series, 4000 X Series
Keysight InfiniiVision 5000, 6000 (except 100 MHz), and 7000 Series, software version 5.26.0001 or higher
Keysight Infiniium S Series
Keysight Infiniium V Series, Z Series, 90000 X Series, and 90000 Q Series, with N5449A adapter
Keysight Infiniium 8000 and 54830 Series, software version 5.7
Keysight 9000 Series, software version 2.0
The N2790A 100-MHz high-voltage differential probe enables safe and accurate floating measurements with an oscilloscope. The N2790A probe allows the use of conventional grounded Keysight oscilloscopes for floating signal measurements up to 1400 V differential voltage and 1000 V common-mode voltage.
Due to its high bandwidth and excellent input impedance characteristics, the probe can accurately measure fast transient edges up to 3.5 ns in modern switching power supplies.
The probe is compatible with the Keysight AutoProbe interface, has a 1 Ω input, and is powered by the probe interface of the Keysight oscilloscope.
When probing differential signals in an environmental chamber at extreme temperatures, Keysight offers the N7013A extreme-temperature extension kit. The N7014A is compatible with the N2790A, with a derated bandwidth of 70 MHz. The 70 cm differential cable set and accessories are suitable for a temperature range of -40 °C to +85 °C.