Teledyne LeCroy high-frequency low-volta Teledyne LeCroy Catalog
Teledyne LeCroy high-frequency low-voltage differential probe DH30-PX type 30 GHz high-bandwidth isolated oscilloscope voltage
  • Teledyne LeCroy high-frequency low-voltage differential probe DH30-PX type 30 GHz high-bandwidth isolated oscilloscope voltage

Teledyne LeCroy high-frequency low-voltage differential probe DH30-PX type 30 GHz high-bandwidth isolated oscilloscope voltage

Brand: Teledyne LeCroy

Origin: USA

Isolated Voltage Probe. Detailed specifications are available in the product datasheet.
Overview

LeCroy high-frequency low-voltage differential probes, DH series:


DH08-PB2 - 8 GHz differential probe with ProBus2 interface 

DH08-PL - 8 GHz differential probe with ProLink interface 

DH13-PL - 13 GHz differential probe with ProLink interface 

DH16-PL - 16 GHz differential probe with ProLink interface 

DH20-PL - 20 GHz differential probe with ProLink interface 

DH25-PX - 25 GHz differential probe with ProAxial interface 

DH30-PX - 30 GHz differential probe with ProAxial interface 

DH-CSPHY-PCIE5-CEMX16 - DH series tip - CrossSync PHY PCIe5 CEM x16 

DH-SI-HS - DH series high-sensitivity solder-in tip, 30 GHz BW, 2.0 Vpp range 

DH-SI - DH series solder-in tip, 30 GHz bandwidth, 3.5 Vpp range 

DH-HTEMP - DH series high-temperature solder-in tip, 16 GHz BW, 3.5 Vpp range 

DH-QL - DH series QuickLink adapter, 8 GHz bandwidth 

DH-QL-3SI - DH series QuickLink adapter kit with 3 x QL-SI tips 

DH-PT - DH series PT browser tip, 16 GHz bandwidth, 3.5 Vpp range 




Key features


  • 8 GHz to 30 GHz bandwidth models

  • Low loading and high impedance, minimal signal disturbance


  • Various tip types:

  • Standard and high-sensitivity 30 GHz solder-in tips

  • High-temperature solder-in tip with 1 m lead

  • QuickLink adapter for mixed-signal probing

  • Handheld adjustable point-and-probe tip

  • Front end for connecting an oscilloscope directly to CrossSync PHY protocol analyzer interposers

  • Built-in tip recognition for easy setup and accurate signal reproduction


  • Ideal for debugging and validation:

  • DDR3/LPDDR3

  • DDR4/LPDDR4/LPDDR4X

  • DDR5

  • Other high-speed serial interfaces



 

General-purpose probing to 30 GHz

The Teledyne LeCroy DH Series 8 to 30 GHz differential probes offer a combination of bandwidth, input range, and offset capability to meet any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH Series probes provide excellent loading characteristics and are calibrated with a custom 'tuned' frequency response. Ultra-low loading and flat frequency response ensure accurate measurements.

Smart probes for every application

Two 30 GHz solder-in tips let you choose a 3.5 Vpp input range for general-purpose applications, or high sensitivity with exceptionally low noise. Also available are a 1 m long 16 GHz high-temperature solder-in tip, a 16 GHz browser tip, and a QuickLink adapter for connecting mixed-signal probe tips. The same solder-in, high-temperature, and QuickLink tips are compatible with all DH Series probes and can be interchanged among any probe in the series, providing maximum flexibility in the lab. Each tip contains its own identification and calibration data for accurate signal reproduction and excellent ease of use.

Solder-in tips (DH-SI and DH-SI-HS)

The 30 GHz DH Series solder-in tips are very small, enabling access to signals on tightly packed circuit boards; the 9-inch lead length helps reach difficult-to-probe points. The standard DH-SI solder-in tip has a 3.5 Vpp input range and is well suited for DDR memory and other general-purpose high-speed serial signal applications. For smaller signals where noise performance is critical, the DH-SI-HS high-sensitivity solder-in tip has a 2.0 Vpp input range and excellent noise performance.

High-temperature probe (DH-HITEMP)

For tests that require placing the device in an environmental chamber, the DH-HITEMP tip can separate the solder-in probe tip from the probe amplifier by up to 1 m. This tip has 16 GHz bandwidth, a 3.5 Vpp input range, and an operating temperature range of -40°C to +125°C, making it well suited for environmental testing of various high-speed devices.

Handheld point-and-probe front end (DH-PT)

Where fast access to multiple test points is critical, the DH-PT browser tip provides 16 GHz bandwidth in a convenient 'pencil' form factor. The included free-hand probe stand enables simple hands-free browsing.

CrossSync PHY cross-layer probe (DH-CSPHY)

CrossSync PHY technology enables waveforms from Teledyne LeCroy oscilloscopes and traces from protocol analyzers to be displayed simultaneously, achieving full time correlation of electrical and protocol information. Through a series of CrossSync PHY-enabled interposers and using special DH-CSPHY probe tips, DH series probes can be connected directly to high-speed signal lines.

QuickLink adapter (DH-QL)

The DH-QL adapter allows QuickLink solder-in probe tips to be used with any DH series probe. For embedded system validation and debugging, these probes can be used for analog probing with DH series probes and for digital acquisition with the HDA125 high-speed digital analyzer.

Mixed-signal flexibility

When connected to a Teledyne LeCroy analog differential probe, QuickLink probes provide 8 GHz bandwidth and a flat, well-controlled frequency response. When used with the HDA125 for digital acquisition, they support 3 GHz bandwidth and have industry-leading sensitivity. The HDA125 can acquire and analyze DDR command bus signals and other high-speed digital bus signals together with time-correlated analog signals directly on standard oscilloscope channels.

 


Specifications

DH Series.png

Expand Teledyne LeCroy high-frequency low-volta

* Specifications are subject to change without notice.