MagneLab
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
MagneLab
Categories

Magnelab Current Probe CT Datasheet datasheet.pdf
Magnelab CT Manual -Probemart.pdf
Magnelab Current Probe Datasheet.pdf
Magnelab Pulse Current Transformer CT Overview Dimension Drawing -Probemart.pdf
Magnelab CT Overview -Probemart.pdf
Magnelab CT ()-Probemart.pdf
Magnelab Pulse Current Transformer -Probemart.pdf
Magnelab Current Probe CT Overview -Probemart.pdf
Pulse Current Transformer.pdf
Magnelab ultra-high-speed current transformers (FCT) enable precise isolated measurement of unipolar and bipolar pulses or AC currents.
This product series measures currents from microampere level to 20 kA over a frequency range of 0.5 Hz to 500 MHz.
The FCT output signal is a voltage waveform at a defined transformation ratio of the measured current and can be analyzed on an oscilloscope, RF power meter, spectrum analyzer, or custom interface circuit.
Magnelab FCTs have excellent performance, are offered in 7 ranges and 5 housing sizes, and can be terminated with SMA or BNC connectors.
All FCTs can be supplied with a calibration certificate and factory test data to ensure optimum performance.
For special application requirements, Magnelab can provide customized FCT ultra-high-speed current transformers to meet user requirements.
The FCT can measure pulses with rise times down to below 200 ps (picoseconds) and bandwidths exceeding 2 GHz, as well as continuous pulse-burst signals.
As an ultra-high-speed current transformer, the Magnelab FCT is the current sensor with the highest sensitivity and fastest response worldwide.
______________________________________________________________________________
Main advantages of Magnelab current transformers:
______________________________________________________________________________
Application areas and industries include:
• Laser and plasma research
• EMC and EMI research
• Semiconductor gate switching
• Power system harmonics and transients
• Lightning research and simulated testing
• Capacitors and electrostatic discharge
• Corona wire discharge
• Partial discharge measurement
• Strictly monitor current fluctuations
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV

| Model | Output (V/A) in 1 MΩ | RMS(A) | Maximum peak (A) | Droop (%/us) | Rise time (ns) | Max l.t*(As)in 50Ω | -3db low(Hz) | -3db high(MHz) |
|---|---|---|---|---|---|---|---|---|
| CT-B5.0 | 5 | 2 | 200 | 3 | 0.875 | 0.0001 | 4800 | 400 |
| CT-B2.5 | 2.5 | 5 | 400 | 0.75 | 0.7 | 0.0004 | 1200 | 500 |
| CT-B1.0 | 1.0 | 8 | 1000 | 0.13 | 0.7 | 0.0025 | 200 | 500 |
| CT-B0.5 | 0.5 | 11 | 2000 | 0.03 | 1.75 | 0.01 | 48 | 200 |
| CT-B0.25 | 0.25 | 16 | 4000 | 0.015 | 3.5 | 0.013 | 24 | 100 |
| CT-B0.1 | 0.1 | 25 | 10000 | 0.006 | 7 | 0.013 | 10 | 50 |
| CT-B0.05 | 0.05 | 35 | 20000 | 0.003 | 17.5 | 0.053 | 5 | 20 |
| CT-C5.0 | 5 | 2 | 200 | 3 | 0.875 | 0.0002 | 4800 | 400 |
| CT-C2.5 | 2.5 | 5 | 400 | 0.75 | 0.7 | 0.0008 | 1200 | 500 |
| CT-C1.0 | 1.0 | 11 | 1000 | 0.13 | 0.7 | 0.005 | 200 | 500 |
| CT-C0.5 | 0.5 | 16 | 2000 | 0.03 | 1.75 | 0.02 | 48 | 200 |
| CT-C0.25 | 0.25 | 22 | 4000 | 0.01 | 3.5 | 0.08 | 12 | 100 |
| CT-C0.1 | 0.1 | 35 | 10000 | 0.004 | 7 | 0.167 | 6 | 50 |
| CT-C0.05 | 0.05 | 50 | 20000 | 0.002 | 17.5 | 0.283 | 3 | 20 |
| CT-D5.0 | 5 | 2 | 200 | 3 | 0.875 | 0.0002 | 4800 | 400 |
| CT-D2.5 | 2.5 | 5 | 400 | 0.75 | 0.7 | 0.0008 | 1200 | 500 |
| CT-D1.0 | 1.0 | 11 | 1000 | 0.13 | 0.7 | 0.005 | 200 | 500 |
| CT-D0.5 | 0.5 | 16 | 2000 | 0.03 | 1.75 | 0.02 | 48 | 200 |
| CT-D0.25 | 0.25 | 22 | 4000 | 0.01 | 3.5 | 0.08 | 12 | 100 |
| CT-D0.1 | 0.1 | 35 | 10000 | 0.002 | 7 | 0.5 | 2 | 50 |
| CT-D0.05 | 0.05 | 50 | 20000 | 0.001 | 17.5 | 0.756 | 1 | 20 |
| CT-E5.0 | 5.0 | 2 | 200 | 3 | 0.875 | 0.0002 | 4800 | 400 |
| CT-E2.5 | 2.5 | 5 | 400 | 0.75 | 0.7 | 0.0008 | 1200 | 500 |
| CT-E1.0 | 1.0 | 11 | 1000 | 0.13 | 0.7 | 0.005 | 200 | 500 |
| CT-E0.5 | 0.5 | 22 | 2000 | 0.03 | 1.75 | 0.02 | 48 | 200 |
| CT-E0.25 | 0.25 | 32 | 4000 | 0.01 | 3.5 | 0.08 | 12 | 100 |
| CT-E0.1 | 0.1 | 50 | 10000 | 0.002 | 7 | 0.5 | 2 | 50 |
| CT-E0.05 | 0.05 | 71 | 20000 | 0.001 | 17.5 | 0.756 | 1 | 20 |
| CT-F5.0 | 5.0 | 2 | 200 | 3 | 0.875 | 0.0002 | 4800 | 400 |
| CT-F2.5 | 2.5 | 5 | 400 | 0.75 | 0.7 | 0.0008 | 1200 | 500 |
| CT-F1.0 | 1.0 | 11 | 1000 | 0.13 | 0.7 | 0.005 | 200 | 500 |
| CT-F0.5 | 0.5 | 22 | 2000 | 0.03 | 1.75 | 0.02 | 48 | 200 |
| CT-F0.25 | 0.25 | 32 | 4000 | 0.01 | 3.5 | 0.08 | 12 | 100 |
| CT-F0.1 | 0.1 | 50 | 10000 | 0.002 | 7 | 0.5 | 2 | 50 |
| CT-F0.05 | 0.05 | 71 | 20000 | 0.001 | 17.5 | 0.756 | 1 | 20 |
| CT-CALCERT | Certificate of calibration with amplitude vs.frequency response plots on option | |||||||