Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
Northstar North Star high-voltage divide North Star High Voltage Catalog
Northstar North Star high-voltage divider VD series UHV probe DC-70-400kV (pulse voltage 550 kV) vertical
  • Northstar North Star high-voltage divider VD series UHV probe DC-70-400kV (pulse voltage 550 kV) vertical

Northstar North Star high-voltage divider VD series UHV probe DC-70-400kV (pulse voltage 550 kV) vertical

Brand: North Star High Voltage

Origin: USA

Northstar North Star high-voltage divider DC-70-400kV (pulse voltage 550 kV), division ratio: 10,000:1

Overview

UHV voltage divider — the VD series is mainly used for ultra-high-voltage testing and in applications requiring extremely stable physical characteristics.

The North Star VD series UHV voltage divider is a vertical ultra-high-voltage voltage probe,

Its range is DC to 70–400 kV (pulsed voltage 550KV), accuracy up to 1%, and the VD series division ratio is 10,000:1.

At the same time, the electrical probe of the UHV sensor VD series uses resistors with an extremely low voltage impedance coefficient, and capacitors that are extremely stable with respect to temperature, frequency, and voltage.

All North Star VD series high-voltage probes use patented technology to minimize the proximity effect (stray capacitance) while maximizing test consistency and stability.

The high-frequency and low-frequency tests of the VD high-voltage probe have been precisely calibrated. The cable is also finely compensated, so that accurate measurement can be achieved even when the cable length exceeds the pulse period under test.


Specifications

 

Project VD-70 VD-100 VD-150 VD-200 VD-300 VD-400
Maximum DC/Pulse Voltage (kV) 70/115 100/160 150/230 200/300 300/420 400/550
Maximum AC RMS value (KV) 50 72 108 142 216 290
Maximum Frequency (MHz) 25 20 20 16 12 8
Fastest rise time (ns) 14 17.5 17.5 22 30 44
Cable Length (ft./m) 30 30 30 30 30 30
DCaccuracy
10Hz-1MHz.accuracy 1% 1% 1% 2% 2.5% 3%
>1MHz.accuracy 3% 3% 3% 3% 4% 4%
input impedance (Megohms) 800 1600 2000 2800 5100
or2550
6800
or3400
Height (inches/cm.) 20/50 24/60 30/75 35/88 54/135 72/180
Diameter (in/cm.) 11/28 11/28 12/29 20/50 24/61 24/61
Capacitance (approx. pF) 24 25 27 24 30 30
Base diameter (in/cm) 10/25 10/25 12/30 12/30 28/72 28/72
Standard pressure ratio 10000:1 10000:1 10000:1 10000:1 10000:1 10000:1


Expand Northstar North Star high-voltage divide

* Specifications are subject to change without notice.