Northstar North Star high-voltage divide North Star High Voltage Catalog
Northstar North Star high-voltage divider VD-300 UHV probe (DC300KV/ pulse voltage 420 kV/rms RMS 216 kV) 12 MHz vertical
  • Northstar North Star high-voltage divider VD-300 UHV probe (DC300KV/ pulse voltage 420 kV/rms RMS 216 kV) 12 MHz vertical

Northstar North Star high-voltage divider VD-300 UHV probe (DC300KV/ pulse voltage 420 kV/rms RMS 216 kV) 12 MHz vertical

Brand: North Star High Voltage

Origin: USA

Northstar North Star high-voltage divider VD-300 UHV probe (DC300KV/ pulse voltage 420 kV/rms RMS 216 kV)12 MHz, division ratio: 10,000:1
Overview

Ultra-high voltage divider — VD series is mainly used for testing ultra-high voltages and in scenarios where extremely stable physical characteristics are required.

North Star / Polar Star VD series ultra-high voltage dividers are vertical ultra-high voltage probes,

with a range of DC~70 - 400kV (pulse voltage 550kV), an accuracy of up to 1%, and a VD series division ratio of 10,000:1.

At the same time, the VD series ultra-high voltage sensor probes use resistors with extremely low voltage dependence and capacitors that are extremely stable with respect to temperature, frequency, and voltage.

All North Star VD series high-voltage probes use patented technology to minimize neighboring effects (stray capacitance) while maximizing the consistency and stability of testing.

Both high-frequency and low-frequency tests of the VD high-voltage probes are precisely calibrated. The cables are also finely compensated, so even when the cable length exceeds the period of the pulse being measured, accurate measurements can still be achieved.


Specifications

 

Project VD-70 VD-100 VD-150 VD-200 VD-300 VD-400
Maximum DC/Pulse Voltage (kV) 70/115 100/160 150/230 200/300 300/420 400/550
Maximum AC RMS value (KV) 50 72 108 142 216 290
Maximum Frequency (MHz) 25 20 20 16 12 8
Fastest rise time (ns) 14 17.5 17.5 22 30 44
Cable Length (ft./m) 30 30 30 30 30 30
DCaccuracy
10Hz-1MHz.accuracy 1% 1% 1% 2% 2.5% 3%
>1MHz.accuracy 3% 3% 3% 3% 4% 4%
input impedance (Megohms) 800 1600 2000 2800 5100
or2550
6800
or3400
Height (inches/cm.) 20/50 24/60 30/75 35/88 54/135 72/180
Diameter (in/cm.) 11/28 11/28 12/29 20/50 24/61 24/61
Capacitance (approx. pF) 24 25 27 24 30 30
Base diameter (in/cm) 10/25 10/25 12/30 12/30 28/72 28/72
Standard pressure ratio 10000:1 10000:1 10000:1 10000:1 10000:1 10000:1