Rohde & Schwarz
Categories
Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing
Bookmark
Rohde & Schwarz
Categories

The R&S®RT-ZISO isolated probing system is capable of tackling measurement challenges in high-voltage and fast-switching environments.
The fiber-optic powered architecture electrically isolates the device under test (DUT) while maintaining the highest possible common-mode rejection ratio (CMRR) even at bandwidths up to 1 GHz.
The entire system compensates for thermal drift and gain errors, ensuring first-class signal fidelity.
Key Features
Bandwidths of 100/200/350/500 MHz and 1 GHz, upgradeable
CMRR > 90 dB at 1 GHz bandwidth
± 3000 V differential input range and offset
± 60 kV common-mode range
Dual connections supporting R&S probe interface and SMA interface
Handling the Challenge of Fast Common-Mode Signals
The R&S°RT-ZISO isolated probing system can suppress interference from fast common-mode signals through optical isolation, achieving a CMRR greater than 90 dB at 1 GHz bandwidth.
This is beneficial for high-voltage side gate measurements in complementary switch circuits, especially for wide-bandgap devices.
1 GHz: > 90 dB
500 MHz: > 100 dB
100 MHz: > 115 dB
1 MHz: > 145 dB
The Probe Front End is Crucial
The R&S'RT-ZISO offers multiple probe front ends, among which the MMCX probe front end is the most important for ensuring excellent CMRR performance.
The probing system also supports various interfaces with different attenuation ratios, including jack and wide-jack types. The probe front-end cables are long and easy to shape,
allowing easy access to probing points while applying very low mechanical stress to the points being measured.
Easily Set Up with R&S Oscilloscopes
Connecting the R&S'RT-ZISO to an oscilloscope via the R&S probe interface provides a smooth user experience. The oscilloscope can detect the probe front end and set the corresponding information.
Offset and range control can be easily configured using the oscilloscope. Users can also conveniently utilize all features and functions of the R&S oscilloscope during measurements,
such as excellent waveform capture rates and fast-response FFT functionality.
Investment Protection
The R&S'RT-ZISO isolated probe system can be connected to any oscilloscope with BNC or SMA interfaces. Users can select instruments according to performance requirements.
The R&SRT-ZISO bandwidth can be upgraded based on future needs.
Ensuring Measurement and Operational Safety
The R&S'RT-ZISO meets the CAT I 1000V safety rating. The materials and mechanical structure of the probe system comply with the IEC/EN 61010-31 standard for handheld probes used in electrical measurements.
CAT II 1000V safety rating
Probe front end can be safely connected
Compliant with Class 1 laser product safety standards
——— Related Applications ———
——— Related Products ———
PMK FireFly®FF-1500A optically isolated probe 1.3 GHz/1.5 GHz high CMRR (180 dB) high-voltage 2500 V double-pulse VGS gate /VDS drain voltage
IWATSU multi-channel high-voltage high-frequency optically isolated measurement probe Isolation SE-6000 remote UHV safety test system
CIC high-voltage differential probe DP20-20K-LVC high-precision 0.1% high-frequency isolated high CMRR 20 kV
| optically isolated probeHost Specifications | |||||
| Model | R&B® ZISO-B901 | R&B® ZISO-B902 | R&B® ZISO-B903 | R&B® ZISO-B905 | R&B® ZISO-B910 |
| Bandwidth | , for switching transients of | 200 MHz | 350 MHz | 500 MHz | 1GHz |
| rise time | |||||
| CMRR | 1GHz > 90dB; 500MHz > 100dB; 100MHz > 115dB; 1MHz > 145dB | ||||
| probe tipattenuator Main Specifications | ||||||
| Model | R&B® ZISO-Z101 | R&B® ZISO-Z201 | R&B® ZISO-Z202 | R&B® ZISO-Z203 | R&B® ZISO-Z301 | R&B® ZISO-Z302 |
| interface | MMCX | MMCX | square pin (2.54 mm) |
wide square pin (5.06 mm) |
browser | browser |
| Cable length | 37 cm | 21cm | 32 cm | 38 cm | 120 cm | 120 cm |
| Attenuation ratio | 1.5X | 10X | 25X | 100X | 10X | 100X |
| Input impedance | 50Ω | 10 MΩ | 10 MΩ | 40 MΩ | 10 MΩ | 100 MΩ |
| Input capacitance | 3.7 pF | 3.5 pF | 3.2 pF | 12pF | 4.6 pF | |
| Input Voltage | ± 45V | ± 300V | ±750 V | ± 3000V | ± 300V | ± 3000V |
| Voltage to ground | 1000V CAT III | 1000V CAT III | 1000V CAT III | 1000V CAT III | 300V CAT III | 1000V CAT III |
| Applicable Temperature Zone | 0℃~+40℃ | |||||