Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
T&M non-inductive coaxial shunt SDN-414- T&M Research Catalog
T&M non-inductive coaxial shunt SDN-414-05 high-frequency precision SDN-414 series current probe CVR (2 Watt)Sic/GaN double-pulse Ids measurement
  • T&M non-inductive coaxial shunt SDN-414-05 high-frequency precision SDN-414 series current probe CVR (2 Watt)Sic/GaN double-pulse Ids measurement

T&M non-inductive coaxial shunt SDN-414-05 high-frequency precision SDN-414 series current probe CVR (2 Watt)Sic/GaN double-pulse Ids measurement

Brand: T&M Research

Origin: USA

T&M SDN-414 series low inductance high-frequency coaxial resistor, 0 2% ultra-high precision, 400-2000M high-bandwidth, double-pulse test
Overview

Non-inductive coaxial shunt CVR (Current Viewing Resistor)


T&M CVR high-frequency non-inductive di resistor, designed to monitor pulse generator systems, the extremely high peak power and current input generated by steady-state current loads, and transient current monitoring. In recent years, with the rapid development of power semiconductors and wide-bandgap devices, evaluation of device dynamic performance (double-pulse) requires high-precision capture of the current waveform at device turn-on and turn-off while minimizing the insertion loss of the probe itself.




    Key features:


  • GHz measurement bandwidth, picosecond-level measurement delay;

  • Patented technology, extremely low inductance;

  • Monitoring of continuous signals (W) or high-energy pulses (J);

  • 0.2% resistance accuracy;

  • Maximum power dissipation of 2 W per unit;

  • Standard BNC connector



——————————————————————————————

 Product photos:

   image.png

   Main models are available in 2 exterior styles (as shown above),SSDN has a nut,SDN has two leads。


—————————————————————————————



    Typical applications:


  • Pulsed current applications

  • Calibration laboratories

  • Current detection for phase meters

  • Single-phase angle indicator V-A

  • Three-phase angle indicator V-A

  • Power factor meter

  • High-frequency wattmeter

  • Wideband power meter

  • Power analysis

  • Current transformer calibration

  • Current probe phase delay characterization

  • SCR current measurement

  • Current control for automatic welding machines

  • Measurement of automotive alternator output

  • Fault current detection to determine AC generator bearing wear

  • Electron beam welding

  • Current detection in knock systems

  • Three-phase fault testing in transmission substations

  • Fault detection in modulators

  • Laser system lamp current measurement

  • IGBT chopper current control in electric vehicles

  • Circuit breaker testing


—————————————————————————————————————



Widely used in double-pulse testing of SiC/GaN wide-bandgap semiconductors

Measured example figure:


 SDN demonstration diagram watermark 2.jpg





About the SDN series current-viewing resistor/non-inductive coaxial shunt


The SDN series are non-inductive shunts designed to operate over a wide bandwidth, suitable for AC and DC power systems, and particularly important in impedance measurement and power calibration systems when phase angle and propagation delay are considered. They are very useful for adding to or extending the current range of power analyzers, power meters, phase-angle meters, frequency response analyzers, and multimeters. Used with a phase-angle meter, the SDN series can measure phase angle between voltage-voltage, voltage-current, or current-current, making it well suited for calibration of phase protection relays, electricity meters, and current transformers.

CVRs are rugged high-frequency resistors designed to withstand very high peak power and current input generated by capacitor banks, pulse generator systems, and steady-state current loads. Their linear response over a wide frequency band provides an accurate indication of current magnitude without inductive elements. Inherent in CVR design is the coupling among key electrical parameters such as resistance, passband, energy capacity, and power rating. This means we offer a broad range of standard units covering a wide range of specifications.

Power Rating

Although most CVRs are primarily designed for surge current measurement, their rugged construction and low-temperature-coefficient resistive element make them ideal for many steady-state applications. Therefore, each resistor series specifies an average power rating suitable for continuous current loads. In circuits involving AC or high-duty-cycle pulsed currents, care should be taken not to exceed this rating, as overheating may damage the CVR. If required, we can provide resistors with special construction that raises the standard power rating to high values depending on the model.

Frequency Response

The passband of a CVR is essentially flat from DC to an upper limit, determined mainly by skin effect in the resistive element. The relevant passband is based on the 10% to 90% rise-time response to a current step function generated by a coaxial-line pulse generator. The di/dt of the test pulse exceeds 10^12 A/s.

Resistance Value

Unless otherwise specified, the resistance tolerance of the resistor is ±4% of nominal value. In addition, each unit is supplied with a precision resistance measurement by Kelvin bridge, accurate to ±0.2%. We can supply a wide range of special resistance values for any of our standard units.

Mechanical Design

All coaxial CVRs have silver-plated brass housing construction. The standard output signal connector is BNC; other connectors are available. Large coaxial CVRs use high-current flanges and coaxial threaded-stud input connections. Powertek's flat-configuration CVRs, the W series, were originally developed for flat-plate transmission-line mounting, are available in a wide range of unit widths and input configurations, and have been found particularly useful in applications requiring resistors with very high energy and power ratings.

Global Traceability

All measurements made using CVR series SDN shunts are traceable to national and international standards; through 宝泰's measurement standards. All CVR series SDN shunts are supplied with a certificate of conformity required by quality assurance standards (such as IEC17025 / ISO9001). Independent measurement certification can be performed using UKAS, A2LA, or Z540 / NAVLAP certificates.

 



For more content, please follow the "探头之家" WeChat official account

          Probe Home QR code.jpg


Specifications
SDN-414- 2 Watt Units - 1 7/8 Inch Case

Model

Resistance ohms

Bandpass MHz.

Risetime nsec.

Emax joules

SDN-414-01

0.01

400

1

6

SSDN-414-01

0.01

400

1

6

SPT-414-01

0.01

400

1

6

SDN-414-025

0.025

1200

0.3

3

SSDN-414-025

0.025

1200

0.3

3

SPT-414-025

0.025

1200

0.3

3

SDN-414-05

0.05

2000

0.18

2

SSDN-414-05

0.05

2000

0.18

2

SPT-414-05

0.05

2000

0.18

2

SDN-414-10

0.1

2000

0.18

1

SSDN-414-10

0.1

2000

0.18

1

SPT-414-10

0.1

2000

0.18

1

US precision instruments, NMR research results, patented technology, low inductance, ultra-high-precision resistors, high overload capacity, particularly suitable for pulse current monitoring; additional specifications can be customized.


For other product information and technical consultation, please scan the QR code to follow the 'Probemart' official account or contact the sales engineer.





Expand T&M non-inductive coaxial shunt SDN-414-

* Specifications are subject to change without notice.