Probemart.com | Probes, current sensors & calibration sources for pulsed-power testing

Bookmark Bookmark
Home > Products > Instruments
PMK LILCO current probe 58EH100 precisio PMK Catalog
PMK LILCO current probe 58EH100 precision wideband RF transformer-pulse CT 2500 A/20 MHz
  • PMK LILCO current probe 58EH100 precision wideband RF transformer-pulse CT 2500 A/20 MHz

PMK LILCO current probe 58EH100 precision wideband RF transformer-pulse CT 2500 A/20 MHz

Brand: PMK

Origin: Germany

PMK LILCO current probe 58EH100 type: aperture 58 mm; ratio 0.1 V/A; peak 2500 A, bandwidth 20Hz-20MHz; rise time 20 ns
Overview

LILCO%20Serie x294 EN

PMK LILCO series precision broadband RF current/pulse current sensor CT, with excellent droop characteristics; bandwidth up to 60 MHz supports high-transient current measurements such as large-scale scientific electromagnetic pulses, EMC, pulse currents, and surge currents.


The LILCO® series PMK current transformers have a bandwidth range from mHz to >60 MHz and an input current range from mA to 20 kA, enabling precision high-bandwidth AC current measurement required for various measurement applications. The current transformer can accurately measure large pulsed or continuous input currents, while electrical shielding between input and output reduces the effect of electromagnetic fields on the output.

 

Galvanic isolation between input and output enables the LILCO® series to be used in measurement setups with large potential differences, or in setups where unwanted currents (such as ground loops) occur between input and output.

 

The BNC output of the LILCO® series current transformers allows easy connection to various measurement instruments, such as oscilloscopes, digitizers, network analyzers, spectrum analyzers, power analyzers, and digital multimeters, using only a standard 50 Ω coaxial cable.

 

Changing the input termination of the measuring instrument can improve low-frequency response and I·t capability and can attenuate the output signal. The LILCO® series ATT10BNCS attenuator is used to further improve these specifications while maintaining the high-frequency performance of the current transformer.

 

The inner diameter (in centimeters) of the LILCO® series is included in each model number:

For example, 13E1000 = 13 mm (0.5''), 26G0100 = 26 mm (1.0''), 52GH010 = 52 mm (2.0''), 58M1000 = 58 mm (2.2''), 89M0100 = 89 mm (3.5'')

 

All LILCO® current transformers are supplied with a factory calibration certificate.

 

The dedicated instruction manual for the LILCO series contains much valuable information on the general limitations of using current transformers and how to perform accurate measurements in a single document.®



The LILCO broadband pulse current transformer probe is a high-performance probe designed specifically for high-frequency current measurement and can operate stably in complex current environments. Its design not only meets the requirements for broadband response and durability but also demonstrates excellent performance in droop characteristics, I-t saturation curves, and high-temperature resistance. The probe inner diameter ranges from 13 mm to 89 mm, suitable for interface requirements of different circuit boards or equipment.

Key features: 

1. Broadband response

Bandwidth range: 0.004 Hz to 60 MHz; able to respond quickly to changes in current signals, suitable for accurate measurement at high frequencies.

Interference immunity: the broadband-response design enables the probe to maintain accurate signal transmission in complex current environments.

2. Excellent droop characteristics

Complete waveform reproduction: the probe can still fully reproduce the true waveform after external impact or drop, avoiding signal distortion or data loss.

Impact resistance: suitable for industrial environments requiring high reliability, such as power grid monitoring and communication systems.

3. Excellent I-t saturation curve

Accurate measurement: the probe has a good I-t saturation curve and can accurately capture instantaneous and sustained current values, ensuring the accuracy of measurement data.

Durability: the I-t saturation curve design makes the probe less prone to burnout, reducing the risk of damage under high currents or rapidly changing currents.

4. Wide test current range

Current range: supports current measurement from mA level to 25kA level, capable of meeting the measurement needs of different industrial and electronic equipment.

Multi-scenario applicability: from low current to high current, the probe maintains stable performance and is suitable for power grids, communications, automotive electronics, and other scenarios.

5. Durable and reliable

High-temperature environment adaptability: the probe can operate normally in high-temperature environments from -55℃ to 155℃, suitable for harsh industrial measurement environments.

High-voltage withstand capability: input voltage up to 1250V, capable of meeting measurement needs in high-voltage environments.

6. Flexible operation

Inner diameter compatibility: inner diameter 13mm~89mm, capable of meeting the interface requirements of different circuit boards or equipment and providing flexible installation options.

PMK's LILCO series has established a position in the market mainly due to its favorable I-t characteristic curve and resistance to burnout. If you frequently use CT for measurement and also need to consider probe magnetic saturation, LILCO will be your ideal choice.



Specifications

LILCO Series Datasheet_03.png

Expand PMK LILCO current probe 58EH100 precisio

* Specifications are subject to change without notice.